Setup & troubleshooting

Get your monitoring station ready.

Start with one working source, add the tools you need and save the workspace. These steps cover the Windows desktop app; the Mac alpha has its own setup guide.

Connect a camera and confirm the picture.

  1. Add Picture and choose the camera or capture device from its source selector.
  2. For DeckLink or UltraStudio, use native Blackmagic capture when original code values and signal excursions matter.
  3. For a Windows camera, open Source configuration. Choose DirectShow or Media Foundation when offered; Automatic can try Media Foundation if DirectShow delivers no frame.
  4. If the camera stays unavailable, close other applications using it. A stuck DirectShow driver may require reconnecting the device. Open Troubleshooting to compare capture methods on the same feed.
  5. Confirm the source format and picture, add your preferred tools and save the workspace.

Media Foundation preserves received UYVY and V210 layouts for measurement. A webcam-style path may alter or clip signal values; use the native capture path when those values are the reason for the check.

Open the complete input and signal-path reference

Add the components your workflow needs.

Capture and network inputs

The Windows installer includes .NET. Native Blackmagic capture uses Desktop Video 14.4 or newer. NDI needs the separate NDI Runtime.

Recording and media

Network FFmpeg workflows and Recorder use compatible external FFmpeg. The app offers setup assistance.

Local AI tools

Open App settings → AI models to set up the models for subject selection, body framing and local transcription. Downloads begin when you request them.

Set up subject selection

AJA integration and DJP Transport are experimental. Check them with the equipment and formats you intend to use.

Check the layout on the production computer.

Use representative sources and watch pane cadence as you add scopes. Performance Summary gives local timing observations; Hardware profile helps evaluate optional model backends.

Scope footers show source format, frame rate and the active processing path. Hover for renderer details. If a large layout falls behind, reduce the number or size of views, or review sampling and update-rate settings.

Find and share diagnostic information

Choose About Broadcast Monitor → Open diagnostic logs. Compact local logs rotate at 2 MiB or UTC midnight, retain at most twelve files and expire after three days while the app runs or on its next launch. Repeated faults can shorten that history.

Logs contain no video or audio; source URLs, local and network file paths, and common credential fields are redacted. Review files before sharing. Nothing is sent automatically. For camera capture issues, Copy support details includes capture status and troubleshooting results.

Read the performance reference

Set up ATEM, tally and output selection.

Professional

Install Blackmagic ATEM Switchers software, then open ATEM Configuration from the workspace menu and connect to the switcher address. Check input names and live tally before assigning feeds.

Connection, tally and startup settings

In Professional on Windows, choose ATEM Configuration from the workspace menu. Install Blackmagic ATEM Switchers software, enter the switcher IP address or host name, then connect. The screen reads input IDs, short and long names, types and connectors, plus external-input, total source-object, AUX-route and M/E counts. AUX and M/E counts do not describe physical output connector totals.

Red rows show program tally; green rows show preview tally. A source tallied on both is red and labeled PROGRAM + PREVIEW. Panel or ATEM Software Control changes update the list. Current program/preview assignments for every M/E and AUX sources appear below it. The screen does not capture video or change switcher routing.

Close keeps the connection active for this application session. Disconnect clears the live tally colors and labels retained inventory Last known and Offline. Reconnect manually after a network loss. Save as Startup Defaults saves the address and Connect on startup preference for your Windows user. Enable the checkbox and save for one connection attempt at the next startup; clear it and save to retain only the address. Unsaved edits leave startup defaults unchanged. Connections stop when Professional access is lost or the app exits.

In an external live-video source's configuration, choose a Switcher assignment and enable Show tally on scope pane borders. Hardware inputs use their reported tally; assignable outputs follow their current source, including supported M/E Program/Preview routes. Borders are red for program and green for preview, with program taking precedence. Changing only the assignment does not restart capture or change switcher routing.

Offline setup suggests Input 1 through Input 20 and accepts other integer input IDs. Program and Preview remain available as reserved selections without border tally. Shared-source assignments and the border checkbox save with the workspace, including temporarily unavailable outputs. Unknown or disconnected tally leaves the normal pane border. The underlying model can consume another switcher data adapter without an ATEM connection.

Professional DeckLink video sources can supply shared ancillary tally for all assigned input numbers. Enable Use this DeckLink source for ancillary tally in source configuration; selecting another feed replaces the previous one. A connected ATEM disables the option and takes precedence, while retaining the saved preference for use after disconnect. The selected fallback holds a shared capture lease until it is disabled, overridden or access ends.

The fallback reads Blackmagic embedded SDI tally, with no tally inferred from video pixels. It supplies input flags, not output routing. Missing or unsupported packets, signal loss and stale data clear the highlights.

For an output-fed source, open the primary source gear and choose Output source display under This scope only, then choose Apply; or use the same choices immediately in the scope context menu. Each pane saves its own choice, even when panes share an input. The upper-right save-defaults icon in input settings applies and saves shared settings for that input across restarts, including capture settings, signal interpretation, Camera Base LUT and switcher/tally preferences. Explicit workspace values take precedence; This scope only choices are excluded and stay unchanged. The options are Don't Show Source, Show Source, Select Source on Top, Select Source on Left and Select Source on Bottom. The lower-left label follows the current route; compact source buttons use short names or input numbers, program/preview tally backgrounds and a selected-source outline. Popup tooltips identify sources without resizing the picture area. Hover or click overflow arrows to reach additional sources. The right toolbar remains available.

Select Output Source in the scope context menu works independently of that display setting. These commands reassign only the selected output/AUX route, including an output currently fed by Program. A direct Program assignment stays read-only; the Program bus is not changed. Display preferences save separately for each scope with the workspace; the switcher assignment remains shared by input. Disconnect or lost authorization disables routing. Routing is also locked while a capture feed assigned to the same output feeds a registered cropped source, an active recording, an active output or LUT Builder. Tooltips explain the lock; labels and tally stay visible.

Set up a monitoring output

Keep updates and support close.

When a downloaded Windows update is ready, choose What's new in its banner or the workspace menu. Review changes since your installed version, close to keep monitoring, or choose Restart to update and follow the workspace-save choice.

For help, include the app version, input and format, affected scope, and the steps that reproduce the issue.